Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
JMIR Hum Factors ; 11: e44619, 2024 01 05.
Artículo en Inglés | MEDLINE | ID: mdl-38180799

RESUMEN

BACKGROUND: Wearable devices have been used extensively both inside and outside of the hospital setting. During the COVID-19 pandemic, in some contexts, there was an increased need to remotely monitor pulse and saturated oxygen for patients due to the lack of staff and bedside monitors. OBJECTIVE: A prototype of a remote monitoring system using wearable pulse oximeter devices was implemented at the Hospital for Tropical Diseases in Ho Chi Minh City, Vietnam, from August to December 2021. The aim of this work was to support the ongoing implementation of the remote monitoring system. METHODS: We used an action learning approach with rapid pragmatic methods, including informal discussions and observations as well as a feedback survey form designed based on the technology acceptance model to assess the use and acceptability of the system. Based on these results, we facilitated a meeting using user-centered design principles to explore user needs and ideas about its development in more detail. RESULTS: In total, 21 users filled in the feedback form. The mean technology acceptance model scores ranged from 3.5 (for perceived ease of use) to 4.4 (for attitude) with behavioral intention (3.8) and perceived usefulness (4.2) scoring in between. Those working as nurses scored higher on perceived usefulness, attitude, and behavioral intention than did physicians. Based on informal discussions, we realized there was a mismatch between how we (ie, the research team) and the ward teams perceived the use and wider purpose of the technology. CONCLUSIONS: Designing and implementing the devices to be more nurse-centric from their introduction could have helped to increase their efficiency and use during the complex pandemic period.


Asunto(s)
COVID-19 , Humanos , Vietnam , Pandemias , Pacientes , Hospitales
2.
Am J Trop Med Hyg ; 110(1): 165-169, 2024 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-37983924

RESUMEN

Tetanus is a disease associated with significant morbidity and mortality. Heart rate variability (HRV) is an objective clinical marker with potential value in tetanus. This study aimed to investigate the use of wearable devices to collect HRV data and the relationship between HRV and tetanus severity. Data were collected from 110 patients admitted to the intensive care unit in a tertiary hospital in Vietnam. HRV indices were calculated from 5-minute segments of 24-hour electrocardiogram recordings collected using wearable devices. HRV was found to be inversely related to disease severity. The standard deviation of NN intervals and interquartile range of RR intervals (IRRR) were significantly associated with the presence of muscle spasms; low frequency (LF) and high frequency (HF) indices were significantly associated with severe respiratory compromise; and the standard deviation of differences between adjacent NN intervals, root mean square of successive differences between normal heartbeats, LF to HF ratio, total frequency power, and IRRR, were significantly associated with autonomic nervous system dysfunction. The findings support the potential value of HRV as a marker for tetanus severity, identifying specific indices associated with clinical severity thresholds. Data were recorded using wearable devices, demonstrating this approach in resource-limited settings where most tetanus occurs.


Asunto(s)
Tétanos , Dispositivos Electrónicos Vestibles , Humanos , Frecuencia Cardíaca/fisiología , Tétanos/diagnóstico , Electrocardiografía Ambulatoria , Gravedad del Paciente
3.
Trop Med Health ; 51(1): 20, 2023 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-36998027

RESUMEN

Severe tetanus is characterized by muscle spasm and cardiovascular system disturbance. The pathophysiology of muscle spasm is relatively well understood and involves inhibition of central inhibitory synapses by tetanus toxin. That of cardiovascular disturbance is less clear, but is believed to relate to disinhibition of the autonomic nervous system. The clinical syndrome of autonomic nervous system dysfunction (ANSD) seen in severe tetanus is characterized principally by changes in heart rate and blood pressure which have been linked to increased circulating catecholamines. Previous studies have described varying relationships between catecholamines and signs of ANSD in tetanus, but are limited by confounders and assays used. In this study, we aimed to perform detailed characterization of the relationship between catecholamines (adrenaline and noradrenaline), cardiovascular parameters (heart rate and blood pressure) and clinical outcomes (ANSD, mechanical ventilation required, and length of intensive care unit stay) in adults with tetanus, as well as examine whether intrathecal antitoxin administration affected subsequent catecholamine excretion. Noradrenaline and adrenaline were measured by ELISA from 24-h urine collections taken on day 5 of hospitalization in 272 patients enrolled in a 2 × 2 factorial-blinded randomized controlled trial in a Vietnamese hospital. Catecholamine results measured from 263 patients were available for analysis. After adjustment for potential confounders (i.e., age, sex, intervention treatment, and medications), there were indications of non-linear relationships between urinary catecholamines and heart rate. Adrenaline and noradrenaline were associated with subsequent development of ANSD, and length of ICU stay.

4.
Sensors (Basel) ; 22(17)2022 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-36081013

RESUMEN

Infectious diseases remain a common problem in low- and middle-income countries, including in Vietnam. Tetanus is a severe infectious disease characterized by muscle spasms and complicated by autonomic nervous system dysfunction in severe cases. Patients require careful monitoring using electrocardiograms (ECGs) to detect deterioration and the onset of autonomic nervous system dysfunction as early as possible. Machine learning analysis of ECG has been shown of extra value in predicting tetanus severity, however any additional ECG signal analysis places a high demand on time-limited hospital staff and requires specialist equipment. Therefore, we present a novel approach to tetanus monitoring from low-cost wearable sensors combined with a deep-learning-based automatic severity detection. This approach can automatically triage tetanus patients and reduce the burden on hospital staff. In this study, we propose a two-dimensional (2D) convolutional neural network with a channel-wise attention mechanism for the binary classification of ECG signals. According to the Ablett classification of tetanus severity, we define grades 1 and 2 as mild tetanus and grades 3 and 4 as severe tetanus. The one-dimensional ECG time series signals are transformed into 2D spectrograms. The 2D attention-based network is designed to extract the features from the input spectrograms. Experiments demonstrate a promising performance for the proposed method in tetanus classification with an F1 score of 0.79 ± 0.03, precision of 0.78 ± 0.08, recall of 0.82 ± 0.05, specificity of 0.85 ± 0.08, accuracy of 0.84 ± 0.04 and AUC of 0.84 ± 0.03.


Asunto(s)
Tétanos , Dispositivos Electrónicos Vestibles , Algoritmos , Electrocardiografía , Humanos , Aprendizaje Automático , Redes Neurales de la Computación , Tétanos/diagnóstico
6.
Lancet Glob Health ; 10(6): e862-e872, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35561721

RESUMEN

BACKGROUND: Intramuscular antitoxin is recommended in tetanus treatment, but there are few data comparing human and equine preparations. Tetanus toxin acts within the CNS, where there is limited penetration of peripherally administered antitoxin; thus, intrathecal antitoxin administration might improve clinical outcomes compared with intramuscular injection. METHODS: In a 2  × 2 factorial trial, all patients aged 16 years or older with a clinical diagnosis of generalised tetanus admitted to the intensive care unit of the Hospital for Tropical Diseases, Ho Chi Minh City, Vietnam, were eligible for study entry. Participants were randomly assigned first to 3000 IU human or 21 000 U equine intramuscular antitoxin, then to either 500 IU intrathecal human antitoxin or sham procedure. Interventions were delivered by independent clinicians, with attending clinicians and study staff masked to treatment allocations. The primary outcome was requirement for mechanical ventilation. The analysis was done in the intention-to-treat population. The study is registered at ClinicalTrials.gov, NCT02999815; recruitment is completed. FINDINGS: 272 adults were randomly assigned to interventions between Jan 8, 2017, and Sept 29, 2019, and followed up until May, 2020. In the intrathecal allocation, 136 individuals were randomly assigned to sham procedure and 136 to antitoxin; in the intramuscular allocation, 109 individuals were randomly assigned to equine antitoxin and 109 to human antitoxin. 54 patients received antitoxin at a previous hospital, excluding them from the intramuscular antitoxin groups. Mechanical ventilation was given to 56 (43%) of 130 patients allocated to intrathecal antitoxin and 65 (50%) of 131 allocated to sham procedure (relative risk [RR] 0·87, 95% CI 0·66-1·13; p=0·29). For the intramuscular allocation, 48 (45%) of 107 patients allocated to human antitoxin received mechanical ventilation compared with 48 (44%) of 108 patients allocated to equine antitoxin (RR 1·01, 95% CI 0·75-1·36, p=0·95). No clinically relevant difference in adverse events was reported. 22 (16%) of 136 individuals allocated to the intrathecal group and 22 (11%) of 136 allocated to the sham procedure experienced adverse events related or possibly related to the intervention. 16 (15%) of 108 individuals allocated to equine intramuscular antitoxin and 17 (16%) of 109 allocated to human antitoxin experienced adverse events related or possibly related to the intervention. There were no intervention-related deaths. INTERPRETATION: We found no advantage of intramuscular human antitoxin over intramuscular equine antitoxin in tetanus treatment. Intrathecal antitoxin administration was safe, but did not provide overall benefit in addition to intramuscular antitoxin administration. FUNDING: The Wellcome Trust.


Asunto(s)
Antitoxinas , Tétanos , Animales , Antitoxinas/uso terapéutico , Caballos , Humanos , Inyecciones Intramusculares , Unidades de Cuidados Intensivos , Tétanos/tratamiento farmacológico , Resultado del Tratamiento
7.
Sensors (Basel) ; 22(10)2022 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-35632275

RESUMEN

Sepsis is associated with high mortality-particularly in low-middle income countries (LMICs). Critical care management of sepsis is challenging in LMICs due to the lack of care providers and the high cost of bedside monitors. Recent advances in wearable sensor technology and machine learning (ML) models in healthcare promise to deliver new ways of digital monitoring integrated with automated decision systems to reduce the mortality risk in sepsis. In this study, firstly, we aim to assess the feasibility of using wearable sensors instead of traditional bedside monitors in the sepsis care management of hospital admitted patients, and secondly, to introduce automated prediction models for the mortality prediction of sepsis patients. To this end, we continuously monitored 50 sepsis patients for nearly 24 h after their admission to the Hospital for Tropical Diseases in Vietnam. We then compared the performance and interpretability of state-of-the-art ML models for the task of mortality prediction of sepsis using the heart rate variability (HRV) signal from wearable sensors and vital signs from bedside monitors. Our results show that all ML models trained on wearable data outperformed ML models trained on data gathered from the bedside monitors for the task of mortality prediction with the highest performance (area under the precision recall curve = 0.83) achieved using time-varying features of HRV and recurrent neural networks. Our results demonstrate that the integration of automated ML prediction models with wearable technology is well suited for helping clinicians who manage sepsis patients in LMICs to reduce the mortality risk of sepsis.


Asunto(s)
Sepsis , Dispositivos Electrónicos Vestibles , Países en Desarrollo , Humanos , Aprendizaje Automático , Sepsis/diagnóstico , Signos Vitales
8.
Wellcome Open Res ; 7: 257, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-38601327

RESUMEN

Patients with severe COVID-19 disease require monitoring with pulse oximetry as a minimal requirement. In many low- and middle- income countries, this has been challenging due to lack of staff and equipment. Wearable pulse oximeters potentially offer an attractive means to address this need, due to their low cost, battery operability and capacity for remote monitoring. Between July and October 2021, Ho Chi Minh City experienced its first major wave of SARS-CoV-2 infection, leading to an unprecedented demand for monitoring in hospitalized patients. We assess the feasibility of a continuous remote monitoring system for patients with COVID-19 under these circumstances as we implemented 2 different systems using wearable pulse oximeter devices in a stepwise manner across 4 departments.

10.
Emerg Infect Dis ; 27(1)2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33063657

RESUMEN

We report a superspreading event of severe acute respiratory syndrome coronavirus 2 infection initiated at a bar in Vietnam with evidence of symptomatic and asymptomatic transmission, based on ministry of health reports, patient interviews, and whole-genome sequence analysis. Crowds in enclosed indoor settings with poor ventilation may be considered at high risk for transmission.


Asunto(s)
COVID-19/epidemiología , COVID-19/transmisión , SARS-CoV-2 , Adulto , Trazado de Contacto , Aglomeración , Genoma Viral , Humanos , Masculino , Vietnam/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...